Industrial Chillers from China: Sizing, Refrigerant and Factory Tests
How to size an industrial chiller, compare capacity ratings, check the refrigerant and components, and test a chiller from China before it ships.
By Packsel Consulting, Purchasing insights
Article date: · 3 min read
Updated:
To buy an industrial chiller from China, first size it to your heat load at your actual water temperature and ambient conditions, then compare quotes on rated capacity at those same conditions, compressor brand, refrigerant, and pump and tank design. A chiller rated at one set of conditions can deliver noticeably less at another.
Industrial chillers cool injection molding machines, lasers, food processes, and many other machines. Chinese manufacturers offer air-cooled and water-cooled models in a wide range of sizes.
Size the chiller to the load
The heat load comes from the equipment you need to cool, plus a margin. Ask your equipment supplier for the heat load and required water temperature and flow. Capacity is often quoted in kilowatts or tons of refrigeration.
Compare ratings at the same conditions
A chiller’s capacity changes with the water temperature it delivers and the ambient air temperature around it. Ask every supplier for capacity at your leaving water temperature and your highest summer ambient temperature.
Check the refrigerant
U.S. rules under the AIM Act phase down hydrofluorocarbon refrigerants and restrict some high-GWP refrigerants in new equipment by sector and date. Ask which refrigerant the chiller uses and confirm it is permitted for your application.
Components
Ask for the compressor brand and type (scroll or screw), the condenser and evaporator design, the pump, tank size, and controller. Write them into the order.
Air-cooled or water-cooled
Air-cooled chillers are simpler to install. Water-cooled chillers are more efficient but need a cooling tower and water treatment.
Electrical and safety
Confirm voltage and frequency. Commercial and industrial installations may need listed equipment and panels to meet local codes. See CE vs. UL certification.
Factory test
During factory acceptance testing, run the chiller with a load and record the leaving water temperature, flow, and power draw. Check alarms, leaks, and refrigerant pressures.
Questions to ask the supplier
- What is the capacity at our leaving water temperature and maximum ambient?
- Which compressor brand and type is used?
- What refrigerant is used, and is it permitted for this application in the U.S.?
- What pump flow and head are provided?
- What alarms and safety controls are fitted?
- Is the chiller built for our voltage and frequency?
Water quality and maintenance
Chillers need clean water. Ask about filtration, water treatment, and the materials used in the water circuit. Scale and corrosion reduce performance.
Common problems
- Capacity lower than expected in hot weather.
- Pumps too small for the piping system.
- Refrigerant leaks after shipping.
- Electrical panels that do not meet local code.
Consider a hypothetical plastics plant that sizes a chiller on a mild-day rating. In summer, the leaving water temperature rises and cycle times increase. Sizing on the highest summer ambient would have avoided the problem.
How we test a chiller
On a chiller test, we check the compressor and refrigerant against the order, then run the chiller with a heat load. We record leaving water temperature, flow and power draw, and test the alarms. We check for refrigerant leaks and look at the pump and tank. We note the ambient temperature during the test, because capacity changes with it.
How Packsel Consulting can help
We compare chiller suppliers on the same rating conditions and witness performance tests before shipment.